  Datasheet File OCR Text:
  iec inlet flters fn 9260 general purpose power entry module with fuses approvals n rated currents up to 10a n for one or two fuses n optional medical versions (b type) according to iec/en 60601-1 n snap-in versions (s type) typical applications the fn 9260 power entry module combines an iec inlet, mains filter with excellent filter attenuation and fuses in a small form factor. choosing fn 9260 product line brings you rapid availability of a standard filter associ - ated with the necessary safety acceptances. standard iec connector filters are a practical solution helping you to pass emi system approval in a short time. a wide selection on amperage ratings, output connections, mounting possibilities and filters for medical applications are designed to offer you the desired solution. n exceptional conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior. n b types comply with the requirements of iec/en 60601-1 for creepage and clea- rance, leakage current and high potential testing. n versions up to 10a are available with fuse holder for one or two fuses. n custom-specific versions are available on request. n portable electrical and electronic equipment n medical equipment n small to medium-sized machines and household equipment n single-phase power supplies, switch-mode power supplies n test and measurement equipment features and benefits technical specifications maximum continuous operating voltage: 250vac, 50/60hz operating frequency: dc to 400hz rated currents: 1 to 10a @ 40c max. high potential test voltage: p C> e 2000vac for 2 sec (standard types) p C> e 2500vac for 2 sec (b types) p C> n 760vac for 2 sec (standard types) p C> n 1700vdc for 2 sec (b types) protection category: ip40 according to iec 60529 temperature range (operation and storage): -25c to +85c (25/85/21) design corresponding to: ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to: ul 94v-2 or better mtbf @ 40c/230v (mil-hb-217f): 2,200,000 hours fuse holder: 1 or 2 fuses (?5 x 20mm) typical electrical schematic n e p line cx r 2xl 2xcy n e p load n e p line cx r 2xl 2xcy n e p load fn 261 fn 9260 (b types without y-capacitors)
> components > fn 9260 * maximum leakage under normal operating conditions. note: if the neutral line is interrupted, worst case leakage could reach twice this level. filter selection table fn 9260x-1-06-y 1 (1.2) 373 5.3 0.1 2.2 1000 -06 2 55 fn 9260x-2-06-y 2 (2.3) 373 2.7 0.1 2.2 1000 -06 2 55 fn 9260x-4-06-y 4 (4.6) 373 1.0 0.1 2.2 1000 -06 2 55 fn 9260x-6-06-y 6 (6.9) 373 0.3 0.1 2.2 1000 -06 2 55 fn 9260x-10-06-y 10 (11.5) 373 0.2 0.1 2.2 1000 -06 2 55 fn 9260xb-1-06-y 1 (1.2) 2 5.3 0.1 1000 -06 2 55 fn 9260xb-2-06-y 2 (2.3) 2 2.7 0.1 1000 -06 2 55 fn 9260xb-4-06-y 4 (4.6) 2 1.0 0.1 1000 -06 2 55 fn 9260xb-6-06-y 6 (6.9) 2 0.3 0.1 1000 -06 2 55 fn 9260xb-10-06-y 10 (11.5) 2 0.2 0.1 1000 -06 2 55 fn 261x-1-06-y 1 (1.2) 373 5.3 0.1 2.2 1000 -06 1 55 fn 261x-2-06-y 2 (2.3) 373 2.7 0.1 2.2 1000 -06 1 55 fn 261x-4-06-y 4 (4.6) 373 1.0 0.1 2.2 1000 -06 1 55 fn 261x-6-06-y 6 (6.9) 373 0.3 0.1 2.2 1000 -06 1 55 fn 261x-10-06-y 10 (11.5) 373 0.2 0.1 2.2 1000 -06 1 55 filter rated current leakage current* inductance capacitance resistance input/output fuses weight @ 40c (25c) @ 230vac/50hz l cx cy r connections [a] [a] [mh] [f] [nf] [k?] [qty] [g] for example: fn 9260-1-06-10, fn 9260sb-10-06-20, fn 261s-6-06-30 product selector fn 9260xx-yy-yy-y snap-in range for s version only 10: snap-in range 0.6 to 1.5mm 20: snap-in range 1.6 to 2.5mm 30: snap-in range 2.6 to 3.5mm 06: faston 6.3 x 0.8mm (spade/soldering) 1 to 10: rated current blank: standard version b: medical version (wihtout y-capacitor) blank: standard housing with mounting fanges s: snap-in version, snapper on vertical side per cispr 17; a = 50 ? /50 ? sym; b = 50 ? /50 ? asym; c = 0.1 ? /100 ? sym; d = 100 ? /0.1 ? sym typical filter attenuation fn 9260: 1 to 4a types fn 9260: 6 and 10a types fn 261: 1 to 4a types fn 261: 6 and 10a types
> components > fn 9260 mechanical data fn 9260 / fn 261 fn 9260s / fn 261s panel cut out installation a c b e h g s f d i 6.3 x 0.8 j a b e g f d i j 6.3 x 0.8 n r m p c t fn 9260 fn 9260s tolerances fn 261 fn 261s dimensions a 46 34 0.3 b 35 35 0.3 c 36 0.3 d 41 41 0.3 e 27.8 27.8 +0.3/-0 f 5.5 5.5 0.3 g 32 32 +0.3/-0 h ?3.2 0.1 i 13.8 13.8 j 12.5 12.5 0.3 m r 3.5 r 3.5 n 33 33 +0.3/-0 p 29 29.5 0.3 r m3 s 90 t* 0.6 - 1.5 t* 1.6 - 2.5 t* 2.6 - 3.5 * for selecting the panel thickness, please refer to the filter selector table. all dimensions in mm; 1 inch = 25.4mm tolerances according: iso 2768-m / en 22768-m your local partner: to find your local partner within schaffners global network, please go to www.schaffner.com february 2009


▲Up To Search▲   

 
Price & Availability of FN9260-10-06

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X